Check out our gift ideas for the festive season! 🎁
77,15 €
ATIThe SMB Auto Extreme Stop-Leak has been specially developed for all automotive air-conditioning systems using old-generation R134A (vehicles before 2013) and new-generation HFO1234yf (vehicles after 2013) refrigerants thanks to the 2 adapters include...
See moreOnly 3 in stock
Only 3 in stock
Delivery mode
Collect at store Wambrechies (France) : Free
Home delivery : 39.00€
Sent by MECATECHNIC on: Monday, December 23, 2024
Description Product
The SMB Auto Extreme Stop-Leak has been specially developed for all automotive air-conditioning systems using old-generation R134A (vehicles before 2013) and new-generation HFO1234yf (vehicles after 2013) refrigerants thanks to the 2 adapters included. It provides curative or preventive solutions to all micro-leakage problems in refrigerant gas circuits .
It locates leaks up to 0.5mm in diameter and seals them permanently without reacting with moisture and oxygen, saving you costly repairs (parts and/or labor).
Advantages :
- Universal dosage (1 x 30ml syringe per circuit).
- Ideal for preventive application.
- Permanently seals leaks in rubber and metal parts of air-conditioning systems.
- Compatible with all refrigerant gases (including CFCs, HFCs and HCFCs).
- Contains no polymers (no risk to the compressor).
- Does not react with humidity or oxygen.
- Detectable under UV lamp (tracer function).
- Significantly reduces compressor noise.
- Does not damage the compressor.
- Does not damage A/C system components.
- Does not damage recovery station components during gas refills.
Pre-check (optional):
- Locate the A/C system's low-pressure valve and unscrew its cap.
- Connect a vacuum pump and evacuate the A/C system for 5 minutes.
- Check the vacuum value obtained with a manometer.
- Stop the vacuum pump and check on the manometer that this vacuum value can be maintained for at least 4 minutes.
- If this is not possible, the leak is too large to be repaired with the Leak Stop device.
A simple check can also be carried out easily using the BARDHAL pressure tester (part no. TB15140 sold separately).
Instructions for use:
- Start the air-conditioning system and let it run at full power.
- Unscrew the syringe cap and connect the black or green adapter to the low-pressure valve (the black connector is for circuits equipped with R134A gas, the green connector is for circuits equipped with HFO1234yf gas).
- Insert the leak-stop by pressing down on the syringe plunger.
- Disconnect the fitting and syringe from the low-pressure valve.
- Replace the cap on the low-pressure valve.
- Allow the system to run for at least 30 minutes.
Please observe all safety precautions.
Capacity (ml)
30
Customer review
No commentary about the product
Met Trusted Shops kunnen we direct verbeteren dankzij uw opmerkingen op de MECATECHNIC website
Your questions